BJSSF - HOT ROLLED CARBON STEEL -PLATES
- MSDS: BJSSF
- Manufacturer: USX CORP
- Product Name: HOT ROLLED CARBON STEEL -PLATES
- National Stock Number: 3439-00F013685
Product Identification
Product ID:HOT ROLLED CARBON STEEL -PLATES
MSDS Date:12/01/1987
FSC:3439
NIIN:00F013685
MSDS Number: BJSSF
Responsible Party
PITTSBURGH, PA 15230
US
Emergency Phone: 412-433-5811
Info Phone: 412-433-6840
Cage: FO673
Contractor
Telephone: 412-433-6840
Cage: FO673
Ingredients
RED IRON OXIDE/IRON (III) OXIDE/FERRIC OXIDE/YELLOW FERRIC
CAS: 1309-37-1
RTECS: NO7400000
Fraction By Weight: 96-99%
OSHA PEL 10 MG/M3 (FE)
ACGIH TLV: 5 MG/M3(FE),B2; 9293
ALUMINUM (POWDER)
CAS: 7429-90-5
RTECS: BD0330000
Fraction By Weight: <0.10%
OSHA PEL 15 MG/CUM
ACGIH TLV: 10 MG/CUM (DUST)
CARBON, GRAPHITE
CAS: 7440-44-0
RTECS: FF5250100
Fraction By Weight: <0.70%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 2 MG/M3 TDUST; 9293
MANGANESE, MN COMPOUNDS
CAS: 7439-96-5
RTECS: OO9275000
Fraction By Weight: ABOVE
OSHA PEL (C) 5 MG/M3 DUST
ACGIH TLV: 5 MG/M3 DUST 9293
PHOSPHORUS (YELLOW & WHITE)
CAS: 7723-14-0
RTECS: TH3500000
Fraction By Weight: <0.04%
OSHA PEL 0.1 MG/CUM
ACGIH TLV: 0.1 MG/CUM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
SILICON
CAS: 7440-21-3
RTECS: VW0400000
Fraction By Weight: <0.35%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
SULFUR
CAS: 7704-34-9
RTECS: WS4250000
Fraction By Weight: ABOVE
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: PNEUMOCONIOSIS, ENHANCE THE RISK OF
LUNG CANCER, INFLUENZA-LIKE ILLNESS TERMED METAL FUME FEVER,
CENTRAL NERVOUS SYSTEM DISORDERS, MANGANESE PNEUMONIA, FIBROSIS OF
LUNG TISSUE & OTHER TOXI C EFFECTS. SKIN/EYES: IRRITATION.
Medical Cond Aggravated by Exposure:CHRONIC RESPIRATORY DISORDERS SUCH
AS ASTHMA, CHRONIC BRONCHITIS, EMPHYSEMA.
First Aid
First Aid:INHALATION: REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT OR
HAS STOPPED, ADMINISTER ARTIFICIAL RESPIRATION OR OXYGEN AS
INDICATED. TREAT METAL FUME FEVER BY BED REST & ADMINISTER A PAIN &
FEVER REDU ING MEDICATION. SKIN: FLUSH AREA W/COLDWATER. EYES:
FLUSH W/PLENTY OF WATER. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Unusual Fire/Explosion Hazard:NOT FLAMMABLE OR COMBUSTIBLE. STEEL
PRODUCTS IN THE SOLID STATE PRESENT NO FIRE OR EXPLOSION HAZARD &
DON'T CONTRIBUTE TO THE COMBUSTION OF OTHER MATERIALS.
Accidental Release
Spill Release Procedures:NOT APPLICABLE TO STEEL IN THE SOLID STATE.
Handling
Handling and Storage Precautions:OPERATIONS W/THE POTENTIAL FOR
GENERATING HIGH CONCENTRATIONS OF AIRBORNE PARTICULATES SHOULD BE
EVALUATED/CONTROLLED AS NECESSARY.
Other Precautions:AVOID BREATHING METAL FUMES &/OR DUSTS. DON'T
CONTINUE TO USE GLOVES OR WORK CLOTHING THAT HAS BECOME SATURATED
OR SOAKED THROUGH W/OIL COATING.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED DUST/FUME RESPIRATORS SHOULD
BE USED TO AVOID EXCESSIVE INHALATION OF PARTICULATES. APPROPRIATE
RESPIRATOR SELECTION DEPENDS ON THE MAGNITUDE OF EXPOSURE.
Ventilation:LOCAL EXHAUST SHOULD BE PROVIDED WHEN WELDING, BURNING,
SAWING, BRAZING, GRINDING, OR MACHINING TO PREVENT DUST/FUME.
Protective Gloves:PROTECTIVE
Eye Protection:SAFETY GLASSES, GOGGLES
Other Protective Equipment:AS REQUIRED DEPENDING UPON THE CONDITIONS OF
USE & SPECIFIC WORK SITUATIONS.
Work Hygienic Practices:WASH HANDS & ANY AREA AFTER CONTACT W/SOAP &
WATER OR WATERLESS HAND CLEANER.
Supplemental Safety and Health
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:2750F
Spec Gravity:7.85
Solubility in Water:INSOLUBLE
Appearance and Odor:METALLIC GRAY SOLID, NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACID
Stability Condition to Avoid:TEMPERATURES >2750F
Hazardous Decomposition Products:OXIDES OF IRON, ALLOYING ELEMENTS, &
HYDROGEN
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.